Meaning: The nozzle placement type is set to either Skew or Offset Skew. The value for N2 cannot be less than or equal to the value for N3 for these placement types.
Recovery:
-
Set Locate Filters to the nozzle type.
-
Select the nozzle in error.
-
In the Properties View, change the value for N2 to be greater than the value for N3. Or, change the placement type, and define new placement values.