Meaning: The Synchronize Model with Catalog command in Project Management was run while the object was read-only. The object was read-only either because the Status was set to something other than Working, or the user who ran the synchronization did not have write permission to the object.

Recovery: If the cause was the object having a status not set to working:

  1. Select the object in error.

  2. Change the Status of the object to Working in the Properties View.

  3. Start Project Management, and then click Tools > Synchronize Model with Catalog.

    -OR-

  4. Click Synchronize out of date occurrences in workspace Refresh on the Window Tab.

    Synchronize Workspace with Catalog Dialog displays.

  5. Select the object in error, and then click Update.

    The software updates the object and removes it from the To Do List.

If the cause was the user not having write permission to the object:

  1. Start Project Management as a user with write access to the object.

  2. Click Tools > Synchronize Model with Catalog.

  3. If you have a global workshare configuration, run Synchronize Model with Catalog at each location.