Could not identify the appropriate leaf system to use as the tripping bracket support - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13.1

Meaning: Could not identify the appropriate leaf system to use as the tripping bracket's support, based on the point obtained from the root system. For example:

  • The software could not retrieve the leaf systems from the root system.

  • The point resides on the portion of the root system that is outside of the bounded area.

  • There is an opening at the location of the point and the point does not fall on the plate or profile.

Recovery:

  1. Verify that the inputs intersect.

  2. Update any inputs that are on the To Do List.

  3. Verify that the point lies within the boundaries of the leaf system.

  4. If the problem persists, report steps taken to your support group.