Flush frame connection is missing the supported member system. Change connection to unsupported and then re-select the supporting member. - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3Dx Help

Language
English
Product
Intergraph Smart 3D
Subproduct
3Dx
Search by Category
Help
Smart 3D Version
13.1

Meaning: The member to be flush was not provided as an input into defining the flush frame connection. This is an internal software failure where not all the inputs were provided to the flush connection.

Recovery:

  1. Open the Structure task.

  2. Click Select .

  3. Set the Locate Filter to Frame Connections.

  4. Select the frame connection in error.

  5. Select More from the Connection box on the ribbon.

  6. Click Flush in the tree view.

  7. Select the flush connection that you want (top, bottom, left, or right).

  8. Redefine the end location of the member.