Set Circuit Sequence Dialog - Intergraph Smart Electrical - Help - Hexagon

Intergraph Smart Electrical Help

Language
English
Product
Intergraph Smart Electrical
Search by Category
Help
Smart Electrical Version
10

This dialog allows you to change the sequence of circuits of a selected bus.

You can change the sequence by doing one of the following:

  • Select a row and select the Up and Down arrows.

  • Drag a row up or down the list. You can see a tooltip that indicates the selected row and the row before or after which the dragged row will be placed.

  • Change the sequence by changing the Starting sequence and Increment by values. Note that you cannot enter 0 (zero) in either field.

Starting sequence

Allows you to enter a value that will determine the starting sequence of the circuits for the current bus.

Increment by

Allows you to enter a value by which you want to increment the sequence of all the circuits belonging to the current bus.

Sequence

Displays the current sequence number of a circuit.

Circuit Item Tag

Displays the item tag of a circuit.

Circuit Type

Displays the type of a circuit.

Cell Item Tag

Displays the cell item tag of a circuit.

Circuit Description

Displays the description of a circuit if available.

  • Setting the sequence of circuits within cells not in a consecutive manner can cause a haphazard or incorrect placement of these circuits in generated SLDs. Some of the circuits in these SLDs may be drawn within cell frames to which they do not belong. Furthermore, there might be an overlap of cell frames. If the software detects that some of the circuits are not ordered consecutively, a warning message is displayed that prompts you to change the circuit sequence in a consecutive manner.

  • Also note that couplers are always placed in the rightmost position of the bus and their respective bus risers are placed in the leftmost position regardless of their sequence numbers.