Place Symbol Connect Points - Intergraph Smart Electrical - Help - Hexagon

Intergraph Smart Electrical Help

Language
English
Product
Intergraph Smart Electrical
Search by Category
Help
Smart Electrical Version
10
  1. In Catalog Manager, open the required .sym file.

  2. On the Catalog Tools toolbar, select Place Points PPM All Outputs Graphic.

  3. From the Connection Type list, select the connection type required.

  4. Select the symbol at the location where you want to add the connect point.

    The software displays a dynamic dashed line representing the connection of the new connect point.

  5. Orient the dashed line to represent the appropriate connection angle for the new connect point. You can also type the exact angle value in the Connect angle field to define the connection angle.

  6. After the connection angle is correct, select again to place the connect point.