Define a Neutral Earthing Connection for Generators - Intergraph Smart Electrical - Help - Hexagon

Intergraph Smart Electrical Help

Language
English
Product
Intergraph Smart Electrical
Search by Category
Help
Smart Electrical Version
10

The following procedure explains how to define a neutral earthing connection for a generator by creating a neutral earthing connection branch under a particular generator in the Electrical Engineer.

  1. In the Electrical Engineer, under a generator, create an independent branch that starts with a power cable or busway.

  2. Right-click an appropriate generator and then select Common Properties on the shortcut menu.

  3. Select the Electrical Data tab.

  4. Under the Neutral Earthing box, select Find.

  5. On the Find dialog, select Find Now and then choose an appropriate child power cable or busway that will be connected to the non-power connection point of the generator symbol in an SLD.

  6. Select OK to return to the Electrical Data tab of the Generator Common Properties dialog.

  7. Generate an SLD for that generator.

  • After generating an SLD, the diagram will display the neutral earthing branch connected to a non-power connection point of the generator.

  • If you are using custom symbols for your generators in SLDs, make sure that they have an additional non-power connection point. Alternatively, you can use one of the symbol provided in the shipped data.