This procedure explains how to apply a reference terminal strip configuration to a terminal strip. Applying a reference configuration to a terminal strip saves time when creating terminal strips.
-
In the Electrical Index or Reference Data Explorer, expand the hierarchy of the Electrical Equipment folder as necessary to display the Terminal Strips folder.
-
Expand the Terminal Strips folder and then right-click a terminal strip that you require.
-
On the shortcut menu select Common Properties.
-
On the Terminal Strip Properties box, select Configuration.
-
On the Terminal Strip Configuration box, select Find.
-
On the Find box, select Find Now.
-
In the Results data window, select an appropriate terminal strip configuration and select OK.
-
On the Terminal Strip Configuration box, select OK.
-
The software does not allow you to apply a reference terminal strip configuration to a terminal strip that has already been wired.
-
If you apply a reference terminal strip configuration to a terminal strip that already has a terminal strip configuration, the replaces the existing configuration with the reference configuration that you are applying.