Option Switch 82: Center of Gravity/Weight Output - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the generation and output of additional weight information not covered by Option Switch 42, plus a full range of center of gravity (CoG) positions. You can also use this option switch to control outputs for either single isometrics or the complete pipeline.

Switch Settings

The following settings are available for Option Switch 82:

SWITCH POSITION 1 - Outputs Suppressed by Single Isometric or by Complete Pipeline

0

None of the outputs controlled by this option switch are required.

1

All nominated outputs are required per drawing or per spool drawing.

2

All nominated outputs are required per complete pipeline.

SWITCH POSITION 2 - Output of Wet (Full) Weight

0 or Blank

Suppress output of wet weight.

1

Output wet weight.

SWITCH POSITION 3 - Output of Insulation Weight

0

Suppress output of insulation weight.

1

Output insulation weight.

SWITCH POSITION 4 - Output of Dry (Empty) CoG Positions

0 or Blank

Suppress output of dry (empty) CoG positions.

1

Output dry (empty) CoG positions.

2

Output dry (empty) + insulation CoG positions.

3

Output dry (empty) CoG and dry (empty) + insulation CoG positions.

SWITCH POSITION 5 - Output of Wet (Full) CoG Positions

0

Suppress output of insulation weight.

1

Output wet (full) CoG positions.

2

Output wet (full) + insulation CoG positions.

3

Output wet (full) CoG and wet (full) + insulation CoG positions.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 64 - Weight / C of G Facility

7.2.0

FEB 1995

Related Option Switches

Option Switch 41: Bore/Dimension/Weight Control

Option Switch Detail Sketch