Controls the generation and output of additional weight information not covered by Option Switch 42, plus a full range of center of gravity (CoG) positions. You can also use this option switch to control outputs for either single isometrics or the complete pipeline.
Switch Settings
The following settings are available for Option Switch 82:
SWITCH POSITION 1 - Outputs Suppressed by Single Isometric or by Complete Pipeline
0 |
None of the outputs controlled by this option switch are required. |
1 |
All nominated outputs are required per drawing or per spool drawing. |
2 |
All nominated outputs are required per complete pipeline. |
SWITCH POSITION 2 - Output of Wet (Full) Weight
0 or Blank |
Suppress output of wet weight. |
1 |
Output wet weight. |
SWITCH POSITION 3 - Output of Insulation Weight
0 |
Suppress output of insulation weight. |
1 |
Output insulation weight. |
SWITCH POSITION 4 - Output of Dry (Empty) CoG Positions
0 or Blank |
Suppress output of dry (empty) CoG positions. |
1 |
Output dry (empty) CoG positions. |
2 |
Output dry (empty) + insulation CoG positions. |
3 |
Output dry (empty) CoG and dry (empty) + insulation CoG positions. |
SWITCH POSITION 5 - Output of Wet (Full) CoG Positions
0 |
Suppress output of insulation weight. |
1 |
Output wet (full) CoG positions. |
2 |
Output wet (full) + insulation CoG positions. |
3 |
Output wet (full) CoG and wet (full) + insulation CoG positions. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
1.0.0 |
APR 1983 |
Dev. No. 64 - Weight / C of G Facility |
7.2.0 |
FEB 1995 |
Related Option Switches |
||
Option Switch Detail Sketch |
||