Permits simple skewed branch legs to display the normal skew box/triangle enclosure suppressed and replaced by a single pipe length dimension and a text message giving the branch orientation. When used to suppress the normal box enclosure, the value set represents the maximum number of fittings permitted in the branch. Branches found to contain more fittings than this are drawn with the normal skew box/triangle enclosure.

Switch Settings

The following settings are available for Option Switch 70:

SWITCH POSITION 1 & 2 - Suppress Skew Box on Branches

0

Draw all branches with normal skew box/triangle depiction.

Value

Suppress skew box or triangle depiction on branch legs whose number of components is less than or equal to the Value set, and outputs an orientation message.

SWITCH POSITION 3 - Skew Rotation Depiction

0

Output orientation message relative to previous position.

1

Output orientation message relative to primary direction.

SWITCH POSITION 4 - Olet Direction Messages for Primary Directions

0

Omit orientation message if undeveloped olet is in a primary direction.

1

Output orientation message if undeveloped olet is in a primary direction.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 35 - Suppression of Skew Boxes/Triangles on Branch Legs

5.4.1

FEB 1988

8.11.0 Release Notes

8.11.0

APR 2003

9.2.0 Release Notes

9.2.0

MAR 2009

Related Option Switches

N/A

Option Switch Detail Sketch

Skew Indication - Branches (OS 70)