Option Switch 124: Flange Rotation Angles - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the output of flange rotation angles that are used by the fabricator when welding on flanges that have to be rotated away from the normal off-center axes. Although you can use option switch on all types of isometric drawings, it is particularly beneficial with spool isometric drawings.

Switch Settings

The following settings are available for Option Switch 124:

SWITCH POSITION 1 - Flange Rotation Angles Plotted or Not

0

Suppress plotting of flange rotation angles. This is the default setting.

1

Plot flange rotation angles.

SWITCH POSITION 2 - Enclosure Box Type

0

Use un-boxed angle output. This is the default setting.

1

Use a diamond-ended enclosure box.

2

Use a round-ended enclosure box.

3

Use a square-ended enclosure box.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 63B - Flange Rotation Angles

7.1.0

JUN 1994

Related Option Switches

N/A

Option Switch Detail Sketch

Flange Rotation Angles (OS 124)