Option Switch 81: Dimensions (Branches) - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the following functions:

  • Dimensions to the center point of valves and straight through instruments, selectively based upon bore. Works in conjunction with Option Switch 80, which operates on end type.

  • Undimensioned branch legs, selectively based upon bore and/or on the number of components in the branch.

Switch Settings

The following settings are available for Option Switch 81:

SWITCH POSITIONS 1, 2, and 3 - Dimensions to the Center Point of Valves and Straight Through Instruments

0

Dimension valves and instruments whose end points set by Option Switch 80 to their center point. This is the default setting.

Value

Dimension valves and instruments whose end points are set by Option Switch 80 and that have a bore less than or equal to the specified value to their center point. You must specify a Value in 1/16 inches or millimeters, depending upon the bore units.

SWITCH POSITION 4, 5, and 6 - Branches within Specified Bore Range to be Undimensioned

0

Dimension all branches. This is the default setting.

Value

Suppress dimensions for all branches that have a bore less than or equal to the specified value. You must specify a Value in 1/16 inches or millimeters, depending upon the bore units.

SWITCH POSITION 7 and 8 - Branches with a Specified Number of Components to be Undimensioned

0

Dimension all branches. This is the default setting.

Value

Suppress dimensions for branches that have a number of components less than or equal to the specified Value. Gasket and bolt entries are counted as components.

SWITCH POSITION 9 - Tee and Tapped Branch Dimensioning Method

0

Dimension tee and tap branches as normal.

1

Output AText EOP with associated dimension for tap branch dimensions. This is typically used when you define the start of the tap branch that is not at the intersection point.

2

Output AText EOP and associated dimension for tee and tap branch dimensions. All set-on type branches and tap points have been designed where the branch start points are not at the intersection points.

  • Dimensioning behavior of switch positions 4, 5, & 6 and 7 & 8 is conditional on the setting that you have defined for switch 121. For more information, see Option Switch 121: Tapping (Branch Dimensions).

  • Any branch containing pipe (100 record), fixed length pipe (101 record), or pipe block (103 record) will not have branch dimension suppression applied to it.

  • Branch dimension suppression using this option switch does not apply to tapped branches.

  • Depending on your specific requirements, switch positions 4, 5, & 6 and 7 & 8 can work independently of or in conjunction with each other.

  • Switch position 9, setting 2 does not include olet type branches.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 59 - Dimensioning Upgrade

7.0.0

OCT 1994

Related Option Switches

Option Switch 80: Dimensions (To Valve Centers)

Option Switch Detail Sketch

Dimensions - Branches (OS 81)