Option Switch 62: Tracing Indication - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls how tracing indicators are plotted on the isometric drawing. This feature can be turned on or off depending on your requirements. When tracing is turned on, Isogen plots a chain-dotted line on one side of the pipe and, optionally, alongside pipeline components.

Switch Settings

The following settings are available for Option Switch 62:

0

Plot chain-dotted tracing lines (with a gap of 1 mm) alongside pipe only. This is the default setting.

1

Suppress tracing indicators.

2

Plot chain-dotted tracing lines (with a gap of 1 mm) alongside pipe and components.

Switch Layout

 Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 12 - Tracing Indication on Fittings

4.0.0

JUN 1986

Related Option Switches

Option Switch 61: Insulation Indication

Option Switch Detail Sketch

Tracing Indication (OS 62)