Controls the weld number enclosure type and weld number prefix. Weld numbers can optionally have a weld prefix character(s) and a variety of enclosure types. Both the weld number enclosure type and the weld prefix may be separately controlled for shop, site or field and offshore welds.

When the weld number enclosure style is not the original circular type, the weld number size is controlled by Option Switch 4 instead of Option Switch 5.

Switch Settings

The following settings are available for Option Switch 75:

SWITCH POSITION 1 - Weld Number Enclosure Style for Shop Welds

0

Use for weld numbers in a fixed size circle. This is the default.

1

Use for a diamond-ended box.

2

Use for a round-ended box.

3

Use for a small-triangular shaped enclosure.

4

Use for a small-diamond shaped enclosure.

5

Use for a square-ended box.

6

Use for a dynamically sized circle.

7

Use for no weld number enclosure.

8

Use to suppress the display of shop weld numbers to be displayed on the plotted isometric.

9

Use for elliptical weld enclosure.

SWITCH POSITION 2 - Weld Prefix on Shop Welds

0

Suppress weld prefix. This is the default.

1

Add a weld prefix to a weld number.

SWITCH POSITION 3 - Weld Number Enclosure Style for Site/Field Welds

0

Use for weld numbers in a fixed size circle. This is the default.

1

Use for a diamond-ended box.

2

Use for a round-ended box.

3

Use for a small-triangular shaped enclosure.

4

Use for a small-diamond shaped enclosure.

5

Use for a square-ended box.

6

Use for a dynamically sized circle.

7

Use for no weld number enclosure.

8

Use to suppress the display of site/field weld numbers on the plotted isometric.

9

Use for elliptical weld enclosure.

SWITCH POSITION 4 - Weld Prefix on Site/Field Welds

0

Suppress weld prefix. This is the default.

1

Add a weld prefix to a weld number.

SWITCH POSITION 5 - Weld Number Enclosure Style for Offshore Welds

0

Use for weld numbers in a fixed size circle. This is the default.

1

Use for a diamond-ended box.

2

Use for a round-ended box.

3

Use for a small-triangular shaped enclosure.

4

Use for a small-diamond shaped enclosure.

5

Use for a square-ended box.

6

Use for a dynamically sized circle.

7

Use for no weld number enclosure.

8

Use to suppress the display of offshore weld numbers on the plotted isometric.

9

Use for elliptical weld enclosure.

SWITCH POSITION 6 - Weld Prefix on Offshore Welds

0

Suppress weld prefix. This is the default.

1

Add a weld prefix to a weld number.

SWITCH POSITION 7 - Double Line Weld Number Enclosure Style for Shop Welds

0

Use for a single-line circle enclosure.

1

Use for a double-line weld number enclosure. (Use with circular enclosure to get double circles.)

SWITCH POSITION 8 - Double Line Weld Number Enclosure Style for Field/Site Welds

0

Use for single-line circle enclosure.

1

Use for a double-line weld number enclosure. (Use with circular enclosure to get double circles.)

SWITCH POSITION 9 - Double Line Weld Number Enclosure Style for Offshore Welds

0 or
Blank

Use for single-line circle enclosure.

1

Use for a double-line weld number enclosure. (Use with circular enclosure to get double circles.)

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 57 - Welding Facilities

7.6.0

MAY 1996

Dev. No. 89H - Message Enclosures

8.10.0

MAY 2002

Related Option Switches

Option Switch 4: Drawing Text Size
Option Switch 5: Coordinates (Connection/Connectivity)
Option Switch 53: Weld Numbering
Option Switch 54: Weld Plotting
Option Switch 77: Weld Number Allocation at Slip-On Flanges and RPads

Option Switch Detail Sketch

Weld Number - Enclosure/Prefix (OS 75)