Option Switch 97: Skew Depiction (Individual and Overall) - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the way in which skew pipe sections containing branch connections are depicted in terms of the skew indication on the isometric drawing. Such skews may be shown as either a single, overall enclosure or a series of separate box or triangle enclosures, one per branch.

Switch Settings

The following settings are available for Option Switch 97:

SWITCH POSITION 1

0

Use a single, overall box or triangle enclosure around the complete skew section. This is the default setting.

1

Use an individual box or triangle enclosure for each branch.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 53 - ISOPLOT Program Update

6.0.0

MAR 1991

Related Option Switches

Option Switch 99: Skew Depiction (Style)

Option Switch Detail Sketch

Skew Depiction - Individual/Overall (OS 97)