Option Switch 112: Flow Arrows (Pipeline) - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the use of flow arrows that are plotted directly on the pipe. These flow arrows show the direction of the fluid or gas flow in the pipeline.

  • You can also use flow arrows that are plotted alongside in-line fittings, together with or instead of this flow arrow type, on pipe.

  • You must include the relevant switch settings information in the pipeline input data file for this flow arrow type to be generated.

Switch Settings

The following settings are available for Option Switch 112:

0

Enable pipeline flow arrows to be plotted at the default scale factor of 8. This is the default setting.

1

Suppress pipeline flow arrows.

Value

Enable pipeline flow arrows to be plotted at a user-defined scale factor, Where Value represents the user-defined value. The value range is 5-15; the larger the number the greater, the scale factor.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 7 - User Positioned Flow Arrows

3.0.0

APR 1986

Related Option Switches

Option Switch 17: Flow Arrows/Gaskets (Components)

Option Switch Detail Sketch

Flow Arrows - Pipeline (OS 112)