Isogen Version
13.0(2016)

Option Switch 116 also enables the prevention of unwanted skews, but uses a dimension tolerance rather than an angle tolerance.

Example 1: OS 116 = 0

In the following illustration, a 1mm movement in the N/S plane causes a skew to be generated (A).

Example 2: OS 116 = 250

In the following illustration, setting a 2mm cut-off value suppresses the generation of the unwanted skew.

Option Switch 115 uses an angular tolerance to control skew generation. Of the two option switches, using Option Switch 116 is the preferred method; however, if both are set, Option Switch 115 takes precedence.