Controls two functions related to the generation of DGN-format isometric output files.
On platforms that support the generation of DGN files, the Option Switch controls the creation of a link file between the Isogen system and the DGN software.
An additional option lets you select ASCII text characters (as an alternative to Vector text) for use within the DGN file.
Switch Settings
The following settings are available for Option Switch 138:
SWITCH POSITION 1, 2, and 3 - Currently Unused
0 |
This switch position must always be set to 0. |
SWITCH POSITION 4 - Generation of ASCII characters in the DGN file.
0 |
Generate vector text characters. This is the default setting. |
1 |
Generate ASCII characters. |
SWITCH POSITION 5 - Generation of DGN format output files
0 or Blank |
Generate normal plotfiles as nominated in Option Switch 71 |
1 |
Generate DGN format output files. Option Switch 71 must be set to a value of 6. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
6.0.0 |
MAR 1991 |
Related Option Switches |
||
Option Switch Detail Sketch |
||
N/A |