Ghost Gaps (OS 110) - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Ghost gaps are created in the 3D design system and are used to link related, but unconnected, components such as:

  • One pipeline to another to form a system isometric

  • One part of a pipeline to another part of the same pipeline where the middle section may remain incomplete and unfinished.

The following example shows part of a system isometric that consists of two pipelines. Set OS 110 = 0 to give a standard-sized gap (A). Set OS 110 = 50 to increase the gap size (B).

Gaps may be dimensioned or un-dimensioned, which is controlled from within the 3D design system by defining the appropriate settings in the extracted piping data file. In the previous example, the gaps are un-dimensioned.

See Also

Option Switch 110: Ghost Gaps