Set OS 119 = 0 to plot normal vertical pipe dimensions and elevations at intersection points when the level changes. This is the default setting.
Set OS 119 = 1 to suppress vertical dimensions and replace them with elevation messages.
Set OS 119 = 2 to output vertical dimensions and elevations at all normal dimensioning positions.