Option Switch 114: Specification Break Indication - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the method used for indication of specification breaks (specification changes) on the isometric drawing.

The following optional methods are available:

  • Single specification indication - One boxed message consisting of the new specification reference pointing to the position on the pipeline where the change occurs.

  • Dual specification indication - Two boxed messages containing the current and new specification references respectively, positioned at the point on the pipeline where the change occurs.

You can also specify the enclosure type of specification break.

Switch Settings

The following settings are available for Option Switch 114:

SWITCH POSITION 1 - Specification Break Style

0

Obtain the single specification break indication box.

1

Obtain the dual specification break indication boxes.

SWITCH POSITION 2 - Specification Break Enclosure

0

Use a square-ended box enclosure. This is the default setting.

1

Use no enclosure.

2

Use diamond-ended box enclosure.

3

Use round-ended box enclosure.

4

Use hexagonal-ended box enclosure.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 15 - Spec. Break Indication

5.0.0

OCT 1986

9.2.0

MAR 2009

Related Option Switches

N/A

Option Switch Detail Sketch

Specification Break Indication (OS 114)