Creates two reserved areas across the bottom of the isometric drawing. One area stretches across the bottom part of the drawing region, while the other area stretches across the bottom of the material list. Once set, both areas are reserved on the drawing frame for related project/pipeline information, and Isogen does not automatically plot any information in either area.
You can use the frame text positioning facility to add information that is included in the pipeline input data file in these areas.
Switch Settings
The following settings are available for Option Switch 35:
SWITCH POSITIONS 1, 2, & 3 - Reserved Area within the Drawing Region
0 |
Allow no reserved area. This is the default setting. |
Value |
Reserve an area equal to the depth of the required area along the bottom of the isometric drawing as specified, measured in whole millimeters up from the outer line of the drawing frame. |
SWITCH POSITIONS 4, 5, & 6 - Reserved Area at the Bottom of the Material List
0 |
Allow no reserved area. This is the default setting. |
Value |
Reserve an area equal to the depth of the required area along the bottom of the material list as specified, measured in whole millimeters up from the outer line of the drawing frame. |
SWITCH POSITION 7, 8, & 9 - Reserved Area at the Top of the Material List
Value |
Reserve an area equal to the depth of the required area along the top of the material list as specified, measured in whole millimeters up from the outer line of the drawing frame. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
1.0.0 |
APR 1983 |
Dev. No. 56 |
7.0.0. |
OCT 1984 |
Related Option Switches |
||
Option Switch Detail Sketch |
||