Controls the amount of extra pipe that is added under the following circumstances:
-
At loose flange and field fit weld (FFW) positions. Extra pipe is added to cut pipe length dimensions and pipe quantities on the material list. There are separate settings to control on-shore and off-shore values.
-
For shop test purposes when certain welds are cut off together with a short length of pipe after testing.
Switch Settings
The following settings are available for Option Switch 22:
SWITCH POSITIONS 1, 2, and 3 - FFW / Loose Flange Allowance (On-Shore)
0 |
Set the allowance to 0 mm. This is the default setting. |
Value |
Set an alternative allowance in whole millimeters. |
SWITCH POSITIONS 4, 5, and 6 - FFW / Loose Flange Allowance (Off-Shore)
0 |
Set the allowance to 0 mm. This is the default setting. |
Value |
Set an alternative allowance in whole millimeters. |
SWITCH POSITIONS 7, 8, and 9 - Shop Test Weld Allowance
0 |
Set the allowance to 0 mm. This is the default setting. |
Value |
Set an alternative allowance in whole millimeters. This setting is only applied to shop test welds. |
Switch Layout
Related Program Development Specifications |
Version |
Date |
Introduced |
1.0.0 |
APR 1983 |
Dev. No. 57 - Welding Facilities Upgrade |
7.0.0 |
OCT 1993 |
Dev. No. 63 - Flat Spool Facility |
7.1.0 |
JUN 1994 |
Related Option Switches |
||
N/A |
||
Option Switch Detail Sketch |
||