Option Switch 25: Material List Position/Title Block Position - Isogen - Reference

Isogen Option Switches Reference

Language
English
Product
Isogen
Search by Category
Reference
Isogen Version
13.0(2016)

Controls the following aspects of the material list:

  • Position of the material list on the isometric drawing.

  • Position of the title block on the isometric drawing.

Switch Settings

The following settings are available for Option Switch 25:

SWITCH POSITION 1 - Material List Position

0

Print the material list on the left-side of the isometric drawing. This is the default setting.

1

Print the material list on the right-side of the isometric drawing.

SWITCH POSITION 2 - Title Block Position

0

Print the title block in the default position (bottom right-corner of the pipeline drawing area).

1

Print the title block at the bottom of the material list.

2

Suppress output of the title block.

SWITCH POSITION 3 - Default Weld Box Position

1

Print weld box at bottom right corner of drawing.

2

Print weld box at bottom left corner of drawing.

Switch Layout

Related Program Development Specifications

Version

Date

Introduced

1.0.0

APR 1983

Dev. No. 56 - User Defined Material List

7.0

OCT 1993

8.8.0

JUN 2001

Related Option Switches

N/A

Option Switch Detail Sketch

Material List - Position (OS 25)