Default value: 0
Allowed values: 0, 1, 2, or 3
Displays graphics for components connected to the selected item (component or line) for the Isometric.
If a line number is selected for the ISO, the entire line is considered the selected component. Continuation graphics will display at the end of the line.
Using Isogen Batch will include the continuation line number with the continuation coordinates.
-
0
No continuation graphics are displayed when running Isogen.
-
1
First continuation level components (components directly connected to the selection) are displayed as continuation graphics.
This option is automatically applied to Stop Signs and Isogen defined split points. For more information, see Stop Sign or I-Configure.
-
2
First and second continuation level components (components directly connected to first continuation level) are displayed as continuation graphics.
-
3