Rigid Element - CADWorx - Help

CADWorx Plant

Language
English
Product
CADWorx
Subproduct
Plant
Search by Category
Help
Smart Isometrics Version
8
Spoolgen Version
10
CADWorx Version
20.2
CADWorx Structure Version
4.2

Mouse Icon Misc toolbar: Rigid Element Rigid Element

Keyboard Command line: ELEMENT

Places a CAESAR II element in the drawing.

Used with CAESAR II (pipe stress analysis software) when a rigid component is required. This is convenient when using a rigid from the base of a pump to the pump discharge piping, or placing a rigid as a structural member that might be supporting the pipe.

When using the CAESAR II bi-directional link or importing a stress input file, rigids can be automatically placed. These rigids are used by the bi-directional link and should not be modified in any manner. They can be moved with a piping system, but they need to remain in their relative location. They are often used when the length of a CAESAR II component does not match the components contained within CADWorx.

These elements are represented with a polyline that has pointed ends. Specify where rigid elements display from the LayerByLineNumber configuration setting.