Change the specification of a model with branches automatically - CADWorx - Help

CADWorx Plant

Language
English
Product
CADWorx
Subproduct
Plant
Search by Category
Help
Smart Isometrics Version
8
Spoolgen Version
10
CADWorx Version
20.2
CADWorx Structure Version
4.2
  1. Click Change Spec Change Spec Icon. Alternatively, type CHANGESPEC on the command line, and press ENTER.

  2. Press ENTER for automatic.

  3. Select a pipeline.

  4. Select a specification.

    The software selects the default component if there is only one default component.

    OR

    The software selects the optional component if there is no default and only one optional.

    OR

    A list of components displays.

    This list only displays when there are multiple components matching the component in the chosen specification. Automatic option only displays the default components if there are matching default components found, even if matching optional components exist. The default component takes higher priority. The only time the software displays an optional component (or list of components) is when there are no matching default components found in the chosen specification. If the software selects the only available default component, skip to step 6.

  5. Select the component you need.

  6. Select the branches.

    If you do not select the branches in step 6 the specification changes only for the tee or cross components. It does not change for the branch piping.

  7. Select a component to keep its position, or press ENTER to finish.

    The software continues to prompt you for selection of a component until you press ENTER to finish.

    The specification assignment for the selected system is changed. If there is a reducer in the system, the new specification assignment only applies up to and including the reducer, not the pipeline on the other side of the reducer.