AlphaSizeControl - CADWorx - Help

CADWorx Plant

Language
English
Product
CADWorx
Subproduct
Plant
Search by Category
Help
Smart Isometrics Version
8
Spoolgen Version
10
CADWorx Version
20.2
CADWorx Structure Version
4.2

Default value: 0
Allowed values: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, or 10

Controls the number of decimal places used in Alpha Size. Setting this variable to zero places no decimals in Alpha Size. Setting the variable to a value from 1 to 9 places 1 to 9 decimal places in Alpha Size. Setting this variable to 10 suppresses trailing zeros in Alpha Size.

Example with a value of 0:

  • For Imperial pipe size: 4 1/2" would be 4 1/2" or 6" would be 6"

  • For Metric pipe size: 50 would be 50 or 60.3 would be 60

Example with a value of 3:

  • For Imperial pipe size: 4 1/2" would be 4.500" or 6" would be 6.000"

  • For Metric pipe size: 50 would be 50.000 or 60.3 would be 60.300

Example with a value of 10:

  • For Imperial pipe size: 4 1/2" would be 4.5" or 6" would be 6"

  • For Metric pipe size: 50 would be 50 or 60.3 would be 60.3

If you want decimals to display in Alpha Size in Imperial or Metric, the recommended setting is 10.