Before you can complete this example, you must first complete the Selection Codes Tutorial which sets up the selection codes.
-
Open CADWorx Plant.
-
Click File > New.
-
Select Imperial.dwt (Metric.dwt.).
-
Click Setup .
-
Click Configuration Settings.
-
Select SpecificationDirectory, and then click the ellipsis .
-
Navigate to [Product Folder]\Plant\Tutorial\Spec, and then click OK.
-
Select Specification / Size.
-
Click Browse.
-
Select Tutorial_Inch.prj (Tutorial_Metric.prj)
-
Click 150 (150 MM) in Specifications, and then click 4" (100) for main and 2" (50) for reduction.
-
Click Piping Rules.
-
Set Apply Gasket Insertion Rule and Apply Bolt Insertion Rule to Flanges Only.
-
Set Apply Flange Insertion Rule to Show Options.
-
Click Apply and Close.
-
Click Nozzle Generic Attach . Alternatively, type ENGENERIC on the command line, and press ENTER.
-
Select the nozzle flange face point in the drawing.
-
Select the nozzle buttweld end point in the drawing.
The Nozzle Generic Attach (Edit) dialog box displays.
-
Type Equip V-1016 Future in the Description box.
-
Type V-1016 Future in the Equipment Name box.
-
Type 0.3370 in the Flange Thickness box.
This must be higher than zero.
-
Leave the Flange Type as RFWN.
-
Select GAS_150, GAS_150A, GAS_150B, and GAS_150C from the Applicable Gaskets list.
-
Select BLT_150, BLT_150A, and BLT_150B from the Applicable Bolts list.
-
Click OK.
The generic nozzle places in the drawing.
-
Select the generic nozzle in the drawing.
A plus grip displays.
-
Click the plus grip point .
A list of available component types displays.
-
Select Flanges, and then select [4"] (100) FLG WELD NECK, 150LB, SCH STD, ASTM A105 Part A.
The selected component inserts with the gasket and bolt allowed by the selected flange.