Redefine a symbol - Intergraph Smart Isometrics - Help - Hexagon

Intergraph Smart Isometrics Help

Language
English
Product
Intergraph Smart Isometrics
Search by Category
Help
Isogen Version
13.0(2016)
Smart Isometrics Version
2019 R1 (7.1)
Spoolgen Version
2019 R1 (9.1)
  1. Select Start > All Programs > Intergraph Smart Isometrics > Symbol Editor to open the symbol editor software.

  2. Select File > Select Project to display the Select Project dialog.

  3. In the Isometric Directory list, select the isometric directory that contains the project to connect.

  4. Select the required project in the Project List, and then select OK.

  5. Right-click a component in the Library Explorer, and select New Symbol from the context menu to display the New Symbol dialog. You can also select a component type in the Library Explorer, and then select Symbol > New Symbol.

  6. Specify the required options for the new symbol.

    • Use the Original SKEY list to specify the standard symbol on which the new symbol is to be based.

    • Select Copy original symbol graphics to make the standard symbol shape available for editing.

    • If the symbol to be redefined is a valve or instrument, use the Spindle SKEY list to specify the required spindle. For example, select the 01SP spindle.

  7. Select OK.

  8. Modify the symbol as needed.

    • Use the commands on the Symbol menu to modify the symbol shape or add tapping points.

    • Select a point in the Edit window, and use the commands on the toolbar and the Symbol menu to draw additional lines for the symbol. Select Undo to correct any mistakes. Right-click to stop drawing lines.

    After you have redefined the symbol, select File > Save to Project.

    The redefined symbol data is stored in the project .xml file. Smart Isometrics can read this .xml file and display the redefined symbol shapes in the pipeline model or output them on the isometric drawing.

  9. Select File > Exit to close the editor.

  • For more detailed information about using the tools and techniques in this workflow, see the Isogen Symbol Editor Help.

  • To display redefined symbols in the pipeline model, you must connect to the same project as was used to redefine the symbol in Symbol Editor.

  • To output redefined symbols on the isometric drawing, you must select Use project symbols on the Generate Drawings Dialog.