Change pipeline bore - Intergraph Smart Isometrics - Help - Hexagon

Intergraph Smart Isometrics Help

Language
English
Product
Intergraph Smart Isometrics
Search by Category
Help
Isogen Version
13.0(2016)
Smart Isometrics Version
2019 R1 (7.1)
Spoolgen Version
2019 R1 (9.1)

You can set a different bore on part or all of a pipeline on-the-fly, such as when you need to introduce a component such as a reducer.

  1. Create a sketch similar to the one shown below. The bore size of the section of pipe labeled 1 is 6-inches:

    Change Bore Example

  2. Select a pipe or component in the Detail window, and then select Tools > Change Bore Command > <Bore Size>. For example, select the pipe marked 1, and then select Tools > Change Bore > 8".

  3. Review the warnings in the Errors window.

  • As the software changes the bore of each component, it looks for the default material for that bore and component type in the specification. If it does not find a default, it uses a generic material. The software reports each of these actions as a warning in the Errors window. In the example below, the software has replaced the fitting tees (T1RCFST-BW) with generic material because it was unable to find a default defined in the attached specification. The default sketch color for generic material is blue, indicating that no length has been defined.

    SPIso DIA Bore Change Results