The order in which the properties display in your view depends on your configuration. Displays properties for pipe end features. A pipe end feature is a logical object that represent either end of a pipe run. You select end features to connect pipe runs.
Approval State
Specifies the status of the selected object or filter. Changing this property sets the Status. The display depends on your access level. You might be unable to change the status of the object. The list is defined by the ApprovalStatus codelist.
Smart 3Dx saves an object to the database when you change that object's status. Use Undo (CTRL + Z) to reverse the status change.
You can only edit or manipulate an object with a status of Working.
Auxiliary Treatment Requirement
Specifies the auxiliary treatment requirement. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Auxiliary Treatment Type
Specifies the auxiliary treatment type for the object. To change the options on the list, edit the Auxiliary Treatment select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Cleaning Requirement
Specifies the cleaning requirement for the object. To change the options on the list, edit the Cleaning Requirement select list in Catalog.
Coating Color
Specifies the color of the object coating. To change the options on the list, edit the Coating Color select list in Catalog. Smart 3Dx includes this property in the painting area report.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Commodity Option
Specifies short code for the primary commodity object from the Piping job specification.
Correlation Approval Status
Specifies whether the object is approved with discrepancies in the three-dimensional data compared with design basis data. The list is defined by the EFWCorrelationApprovalStatus sheet in the AllCodelist workbook.
Topology mismatch approved
Indicates that the object topology mismatch can be ignored.
Data and Topology mismatches approved
Indicates that the object data and topology mismatches can be ignored.
None
Indicates that you do not approve a mismatch.
Correlation Basis
Specifies whether the object is correlated to a P&ID object. The list is defined by the EFWCorrelationBasis select list.
Correlate Object
Indicates that the object has a correlating object in a P&ID.
No correlation is required
Indicates that the object does not have a correlating object in a P&ID.
Correlation Status
Specifies whether the object has been correlated to an object in a P&ID. The list is defined by the EFWCorrelationStatus select list.
Created by
Specifies the name of the person who created the object.
Date Created
Specifies the creation date of the object.
Date Last Modified
Specifies the date of the last modification to the object.
Exterior Coating Area
Specifies the area of the coating for the object.
Exterior Coating Requirement
Specifies the coating requirement for the object. To change the options on the list, edit the Coating Type select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Exterior Coating Type
Specifies the type of coating for the object. To change the options on the list, edit the Exterior Coating Type select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Exterior Surface Treatment Requirement
Specifies the exterior treatment requirement for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Exterior Surface Treatment Type
Specifies the exterior treatment type for the object. To change the options on the list, edit the Exterior Surface Treatment select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Heat Tracing Requirement
Specifies whether the object is heat-traced. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Heat Tracing Type
Specifies the type of heat-tracing. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Heat Tracing Medium
Specifies the heat-tracing medium to apply to the object. To change the options on the list, edit the Heat Tracing Medium select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Heat Tracing Medium Temperature
Specifies the temperature of the heat-tracing medium. Include the unit of measurement of temperature (K for Kelvin, F for Fahrenheit, or C for Celsius, for example).
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value.
Hyperlink
Specifies the URL or local file path associated with the object. Click the hyperlink to open the page or object in your default browser. Point to the hyperlink to display the URL or path as a tooltip.
Description
Specifies the descriptive text associated with the hyperlink.
URL
Specifies the web address or local file name associated with the hyperlink. The URL must include the protocol, such as http: or https:, as well as the domain name. For example, https://hexagonppm.com/.
Insulation Material
Specifies the material of the insulation.
Piping
The software displays this property only when the Insulation Type is Specification Driven or User Defined.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.
User Driven
Allows you to select a value. Click to switch to Rule Driven .
This option displays when the Insulation Type is User Defined.
The User Driven option is not active if it is not present on the parent pipe run.
HVAC
If you select Not Insulated, you cannot change the information in Insulation Thickness.
Select More to select an insulation material from the Catalog. To change the options on the list, edit the Insulation Material select list in Catalog. See Select Insulation Material Dialog.
Insulation Purpose
Specifies the purpose of insulation. The software displays this property only when the Insulation Type is Specification Driven or User Defined. To change the options on the list, edit the Insulation Purpose select list in Catalog.
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.
User Driven
Allows you to select a value. Click to switch to Rule Driven .
This option displays when the Insulation Type is User Defined.
The User Driven option is not active if it is not present on the parent pipe run.
Insulation Specification
Specifies the insulation specification for the object. The software displays this property only when the Insulation Type is Specification Driven.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
The User Driven option is not active if it is not present on the parent pipe run.
Insulation Temperature
Specifies the temperature. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example) when specifying this value. The software displays this property only when the Insulation Type is User Defined or Specification Driven.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
The User Driven option is not active if it is not present on the parent pipe run.
Insulation Thickness
Specifies the thickness of the insulation.
Piping
Rule Controlled
Specifies that a rule defined for a parent property controls the value. If Rule Controlled does not display, you can select a value. This option displays when the Insulation Type is Specification Driven.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven . This option displays when the Insulation Type is User Defined.
User Driven
Allows you to select a value. Click to switch to Rule Driven .
This option displays when the Insulation Type is User Defined.
The User Driven is not active if:
-
It is not present on the parent pipe run.
-
The Insulation Material on pipe feature does not support the value of the Insulation Thickness on pipe run.
HVAC
If you selected Not Insulated in the Insulation Material box, this property is unavailable.
Insulation Type
Specifies the type of the insulation.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Interior Coating Area
Specifies the area of the interior coating for the object.
Interior Coating Requirement
Specifies the interior coating requirement for the object. To change the options on the list, edit the Coating Type sheet in the AllCodeLists.xls workbook in the reference data.
Interior Surface Treatment Requirement
Specifies the interior treatment requirement for the object. To change the options on the list, edit the Interior Surface Treatment select list in Catalog.
Last Modified by
Specifies the name of the person who last modified the object.
NPD
Specifies the nominal piping diameter for the object. If displays in the box, the nominal diameter is derived from a rule and not editable. If the icon does not display, the value is user defined.
NPD Unit Type
Specifies the units for the NPD value. Select mm or in from the list.
Option Code
Specifies options that you can use instead of the selected object, and then updates the object upon selection. If no options exist, this field displays Default. The Option list contains any options defined in the piping specification for the short code selected in the Short Code list. For example, if you are looking at a valve part, the Option list contains other valve parts, such as one with a higher-pressure rating, that you can select.
Outer Diameter
Specifies the outer diameter of the object.
Pipe Run
Displays the pipe run to which the end feature belongs. You cannot change the end feature pipe run.
Pipeline
Displays the pipeline system to which the end feature belongs. You cannot change the end feature pipeline.
Placement Type
Displays all the placement types. The components listed in each placement type are based on the piping specification and nominal diameter of the selected object, and the geometry at the insertion location.
Specification
Specifies the specification of the object. This property is inherited from the parent pipe run.
Rule Driven
Specifies that a rule drives the value. This is the default option. Click to switch to User Driven .
User Driven
Allows you to select a value. Click to switch to Rule Driven .
Steamout Pressure
Specifies the steamout pressure for the object. Include the pressure unit of measure (psi for pounds per square inch for example).
Steamout Requirement
Specifies the steamout requirement for the object. To change the options on the list, edit the Steamout Requirement select list in Catalog.
Steamout Temperature
Specifies the steamout temperature for the object. Include the temperature unit of measure (K for Kelvin, F for Fahrenheit, or C for Celsius for example).
Tag
Specifies a tag that identifies the object.
Type
Specifies the path feature type.