Places a label either above or on center of center line on a linear segment. "Above" is determined by the direction of the line. If no clear space is found, the label is placed on the longest visible segment of the center line of the linear segment. Used by Piping Plan_FlowArrow_Longest Segment.xml.
Customization
granularity
Specifies a portion of the height of a label as the basis for the increment used to find clear space in which to position the label.
-
Type 0 to specify a Coarse setting. With a Coarse setting, the software searches an increment of exactly one width and height of the existing label in order to find clear space in which to place the new label.
-
Type 1 to specify a Medium setting. With a Medium setting, the software searches an increment of exactly one-half the width and height of the existing label.
-
Type 2 to specify a Fine setting. With a Fine setting, the software searches an increment of exactly one-third the width and height of the existing label.
1 - Label Offset
2 - Coarse setting
3 - Medium setting
4 - Fine setting
labelOffset
Allows you to specify the distance from a point placed on the model object to the farthest location from the point that the label can be placed. Use the Label Offset property when you want to place the label within quadrants around the point. The point generator calculates the point. The software starts from the point location and looks outward to the limit of the Label Offset distance, and then begins looking for clear space within which to place the label.
1 - Label Offset |
Specify both the horizontal and vertical distances within which to place the label. Both distances must be the same.