Meaning: This happens for a gusset or corner gusset type assembly connection when the brace's section size is larger than the member being braced or the cardinal point of the brace is such that the face of the brace to mount the gusset plate is outside the braced member.
Recovery: Edit the brace's section size such that it is smaller than the member being braced. Also, verify the cardinal point of the brace is correct with respect to the braced member.