Error Messages: B - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
12.1 (2019)

Both points cannot be placed in the same plane.

  • Meaning: When placing a volume by two points, you cannot place both points in the same plane.

  • Recovery: You must place the points in different planes when placing a volume by two points.

Boundary condition could not be created. Create an Analysis Model prior to assigning any boundary conditions.

  • Meaning: You are trying to define a boundary condition for a member without having an Analysis Model created first. Boundary conditions are assigned to an Analysis Model when they are created. Therefore, an Analysis Model must exist before you can create a boundary condition.

  • Recovery: In the Structural Analysis task, use the New Analysis Model command to create an Analysis Model. Then define your boundary conditions.

Boundary condition "XXX" may not be valid for the given geometrical conditions. Please verify.

  • Meaning: The geometry of the analytical model has changed and the existing boundary condition may not be valid.

  • Recovery: Verify that the identified boundary condition is still valid.

Branch nominal diameter is larger than header nominal diameter.

  • Meaning: While routing, you connected two runs in such a way that the branch run is larger than the header run.

  • Recovery: Modify the header or branch run size such that the branch is smaller than or equal to the NPD of the header.