Failed to extend the profile part’s geometry so that mitering could properly be applied. Therefore, the profile (stiffener or beam) part has not been created or updated. - Intergraph Smart 3D - Troubleshooting

Intergraph Smart 3D Troubleshooting Reference

Language
English
Product
Intergraph Smart 3D
Subproduct
Troubleshooting
Search by Category
Troubleshooting
Smart 3D Version
12.1 (2019)

Failed to extend the profile part’s geometry so that mitering could properly be applied. Therefore, the profile (stiffener or beam) part has not been created or updated. (Structural Detailing)

Meaning: This error is related to profile geometry and is usually geometry-specific. The error occurs for some cases in which stiffeners cross over a plate knuckle.

Recovery:

  1. Verify that the profile system has proper boundaries. Check for knuckles to split the profile system.

  2. Check whether the landing curve of the profile could be modified to avoid knuckles, bends, or complex geometry.

    1. Profile part ends by passing over a bend knuckle of the plate.