Places an assembly connection between a member part and a bounding part. This command creates the assembly connection, applies the appropriate flange and web cuts, and creates the appropriate physical connections. A typical example is the bounding of a member to the flange and web faces of another member.
Member generic assembly connections are typically created automatically with Place Linear Member System Command and connected to a detailed plate system or edge reinforcement. You can use Place Member Generic Assembly Connection in situations where the connection is not created automatically.
The member is bounded to ports at the faces or edges of the bounding part. The ports used can be edited after creating the assembly connection. This command supports the following situations:
-
A member bounded by a plate edge port.
-
A member bounded by a plate face port.
-
A member bounded by a flange edge port.
-
A member bounded by a web or flange face port.
-
The selected bounding geometry must be on detailed parts.
-
This command can generate physical connections to a single plate part.
Place Member Generic Assembly Connection Ribbon
Modify Member Generic Assembly Connection Ribbon
What do you want to do?