To connect two conduit runs using Move :
-
For inline connections, the two conduit ends must be collinear to each other.
-
For branch connections, the header and branch runs must be orthogonal to each other.
-
There should be sufficient space at the connection to accommodate the connecting part. If the space is not sufficient, the software does not make a connection and displays a message suggesting that you connect the conduit runs manually.
-
The software consumes the first available straight feature of the moved conduit run to accommodate the connection thickness, such as a mating part.
-
In a partial move, if the connection results in an overlap the software connects the two ends with a To Do Record to maintain the connectivity.
-
If there is no space to accommodate mating part, the software does not connect the two ends and displays a message suggesting that you to connect the ends manually.
Inline Connection
No. |
Route Object |
Approval Status |
Permission Group Access |
||
1 |
Conduit run A |
Working |
Full control/ Write |
||
2 |
Conduit run B |
Working |
Full control/ Write |
||
3 |
Connection |
||||
Result: The software connects the conduits A and B. |
|||||
No. |
Route Object |
Approval Status |
Permission Group Access |
||
1 |
Conduit run A |
Working |
Full control/ Write |
||
2 |
Conduit run B |
Working |
Full control/ Write |
||
3 |
Transition mating part connecting the conduits |
||||
Result: The software connects the conduits A and B using a mating reducer. Reduction in conduit B length = connection thickness. |
|||||
Branch Connections
No. |
Route Object |
Approval Status |
Permission Group Access |
||
1 |
Header run |
Working |
Full control/ Write |
||
2 |
Branch run |
Working |
Full control/ Write |
||
3 |
Horizontal tee connection associated with the header |
||||
Result: The software connects the header and branch runs at the tee end feature. |
|||||
Equipment Connection
No. |
Route Object |
Approval Status |
Permission Group Access |
||
1 |
Conduit run |
Working |
Full control/ Write |
||
2 |
Equipment |
Working |
Full control/ Write |
||
3 |
Coupling connection |
||||
Result: The software connects the conduit run and equipment at the conduit port on the equipment. |
|||||