In the tree view, click Piping > Piping Specification > Piping Materials Classes.
-
In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Permissible Taps.
-
Click the Insert Row Command to insert a blank row in the grid view.
-
In the Permissible Tap Number column, enter the tap number that you want to allow in the piping materials class.
-
In the Is Preferred Tap column, enter TRUE if the tap number is the preferred tap. Enter FALSE if the tap is not the preferred tap.
-
The tap numbers must be defined using Tap Properties.
-
The Permissible Taps sheet in the Piping Materials Class.xls workbook corresponds to the Permissible Taps node. See Piping Reference Data.