Define Preferred Tap End Stud Bolt length - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
13
  1. In the tree view, click Piping > Piping Specification > Model Rules > Preferred Tap End Stud Bolt Length Rule.

  2. Click the Insert Row Command to insert a blank row in the grid view.

  3. In the Bolt Diameter From column, enter the bolt diameter lower bounds for which to specify a preferred length.

  4. In the Bolt Diameter column, enter the bolt diameter upper bounds for which to specify a preferred length.

  5. In the Bolt Diameter Increment column, enter the value by which to increment the bolt diameter.

  6. In the Material Grade column, enter the material grade code for the bolt.

  7. In the Preferred Bolt Length From column, enter the preferred bolt length lower bound for this bolt diameter and material grade.

  8. In the Preferred Bolt Length To column, enter the preferred bolt length upper bound for this bolt diameter and material grade.

  9. In the Preferred Bolt Length Increment column, enter the value by which to increment the preferred bolt length.

  10. Click the Save Command Save.

The Preferred Tap End Stud Bolt Length sheet in the workbook corresponds to the Preferred Tap End Stud Bolt Length Rule node. See Piping Reference Data.