Define Tap End Stud Bolt Length Calculation Tolerance - Intergraph Smart 3D - Help - Hexagon

Intergraph Smart 3D Catalog

Language
English
Product
Intergraph Smart 3D
Subproduct
Catalog
Search by Category
Help
Smart 3D Version
13
  1. In the tree view, click Piping > Piping Specification > Piping Materials Classes.

  2. In the Piping Materials Classes branch, open a specification and click Piping Materials Class Rules > Tap End Stud Bolt Calculation Tolerance Rule.

  3. Click the Insert Row Command to insert a blank row in the grid view.

  4. In the Bolt Diameter From column, specify the beginning bolt diameter for the tolerance that you want to define.

  5. In the Bolt Diameter To column, specify the ending bolt diameter for the tolerance that you want to define.

  6. In the Bolt Length From column, specify the beginning bolt length for the tolerance that you want to define.

  7. In the Bolt Length To column, specify the ending bolt length for the tolerance that you want to define.

  8. In the Bolt Length Tolerance column, enter the tolerance the software is to use for length calculations for the bolt length and bolt diameter range that you defined.

The Tap End Stud Bolt Len Cal Tol sheet in the workbook corresponds to the Tap End Stud Bolt Calculation Tolerance Rule node. See Piping Reference Data.