The following table lists solutions to common problems that can happen during the conversion process.
Message |
Meaning / Solution |
No SKEY found for Model Code B23. It has been set to NCFL: |
ModelCode B23 in ISOMAP table does not have a corresponding SKEY. |
Can't Find Physical Data File C:\catalogS\BAYERDATA\Physical\TDB23_39_555_130 …. |
The physical data files do not exist. Check the column codes to ensure the correct files are being sought. |
No Description for Commodity Code 655_883 |
A description for this component does not exist in the Short Descriptions File. Check the column codes to ensure the correct Commodity Code is being generated. |
No Dimensions for Component 768803.034.9, NS 26…... |
Physical data does not exist for this component. Check the bore and data file. |
No Bolt Record in PCSD for component with NS .5, Rating 150 |
No bolt record can be found for a particular bolted component. Check units / settings. |
Dimension mapping '' for SKEY ELBW is illegal, ….. |
An Illegal dimension map has been specified. Check the Equation Mapping file / ISOMAP table. |
Invalid mapping for component 6Q2C23_1 Output O4 …… |
The requested Output column does not exist in the physical file. Check the equation.map file. |
Cannot Determine Radius for Trimable Elbow (90 Degree Assumed) |
The angle for the trimmable elbow could not be found in the description. The software has assumed it to be 90 Degrees. |
Information - Radius for Trimable Elbow (90 Degree Assumed) |
The angle as defined by ‘ASTRING’ has not been found; however, more extensive checks have enabled the software to make a decision on the angle. |