Report Status
Controls report generation. If you select Yes, a report is generated and options on the General tab become available for selection. If you select No, a report is not be generated and options on the General tab are grayed out.
General Tab
Item Code/Bores
Locates matching components by item code and bores. This option is mandatory. After the software finds a matching component, you can report on the following optional checks:
-
End preparation - The end preparation of the components.
-
Item code 2 - The second item codes.
-
Configuration - Smart Isometrics configuration codes.
-
Description - Component descriptions.
-
Dimensions - Dimensions with a user-specified tolerance.
-
Bolts - Turns on and off the bolt checking.
Specific Tab
Omit length from fixed pipe codes
Removes the length from fixed length pipe item codes before finding a matching component.
Display dimensional differences
Displays differences that exist with dimensions.
OK
Accepts all changes and closes the dialog box.
Cancel
Cancels all changes and closes the dialog box.
Apply
Accepts all changes without closing the dialog box.
Defaults
Resets all settings in the dialog box to the stored defaults.
Help
Opens the online documentation displays the Help-related topic.