The following tables lists common warning and information messages that can appear in the Errorlog.txt file produced during the PDS conversion process.
Warning Messages
Message |
Meaning |
Warning - Cannot Determine Bolt Data from ...\Physical\xxx - no bolts created for - xxx |
An error occurred when reading the specified bolting file. Check the eden code. |
Warning - Cannot determine range of second bores from Weight Table xxx Component omitted. |
A single bore was specified for a reducing component. The range of second bores must be determined from the weight file. An error occurred trying to read this file. Check the eden code. |
Warning - Cannot find Match in Size Dependent data for xxx Bore xxx No components created. |
A match for the component could not be found in the size dependent data file. Check the units |
Warning - No Description for xxx Bore xxx No components created. |
No match could be found in the short description file for the component. |
Warning - Error Reading Dimension Mapping for xxx with SKEY : xxx |
An error occurred reading the equation.map file or the mapequations.txt file. |
Warning - Cannot determine dimensions for xxx with SKEY : xxx Please provide dimension mapping. |
An error occurred when trying to determine the dimensions from the eden code. Provide mapping for this component. |
Warning - Error Reading physical data file ...\Physical\xxx - no components created for - xxx |
An error occurred when trying to read the physical data file. Check its format / content. |
Warning - Cannot Determine OD for xxx Bore xxx - No Components Created. |
An entry in the TDMALxxx table could not be found for the given OD. Check the units / eden code and or TDMALxxx table. |
Warning - No Value Specified in User Elbolet Data File for xxx Bore xxx - No Components Created. |
An entry for the given bore could not be found in the user specified elbolet dat file. Check the units and the file contents. |
Warning - Cannot find associated component for xxx No Dimensions for this component. |
An associated component could not be found (e.g. tbacking flange / stub end). Check the specification. |
Warning - Error determining component data from pcd entry : xxx |
The component dimensions are missing from the PCD file. Check the value in the modifier column |
Warning - Error Reading Fixed Pipe Length Table xxx |
The format of the fixedpipe.txt file is invalid. |
Warning - Can't find Length in PCSD Modifier code for xxx Component Omitted. |
The component dimensions are missing from the PCD file. Check the value in the modifier column |
Warning - Invalid Mapping for xxx Skey xxx" Component Omitted. |
The mapping as specified in the equation.map or mapequations.txt file is invalid. |
Warning - Invalid mapping for component xxx Output n is Invalid - Component has been omitted." |
Output n has been specified in the mapequations.txt file OR the eden code – this output does not exist. Check the mapequations.txt file or the eden code. |
Warning - NoConfiguration Found for xxx with Skey xxx Component Omitted." |
The skey does not exist in the skey.tbl or the skeyuser.tbl |
Warning - Error Decoding Physical Data File - no component created for xxx |
An error was encounter reading / decoding the physical data source file. Check the eden code. |
Warning - Missing Commodity File ...\Commodity\xxx - no component created for - xxx |
The specified commodity file is missing. Check the eden code. |
Warning - Error Decoding Symbol Processor File ...\Commodity\xxx - no component created for – xxx |
An error occurred reading the symbol processor file. Check the eden code |
Warning - Missing Symbol Processor File ...\Commodity\xxx - no component created for – xxx |
The symbol processor file is missing. Re-extract the commodity data. |
Warning - Cannot find Physical File ...\Physical\xxx - no component created for - xxx |
Cannot find the specified physical data file. Re-extract all the physical data (ensure all practices used are extracted). Check the eden code. |
Warning - Cannot find Physical File Reference from ...\Commodity\xxx - no component created for – xxx |
A reference to the physical data file could not be found. Check the eden code. |
Warning - Error Reading Commodity File ...\Commodity\ - no component created for - xxxAn error occurred reading the commodity file – check eden code. |
An error occurred reading the commodity file. Check eden code. |
Information Messages
Message |
Meaning |
Information - No Match for Component xxx with Bore xxx In Physical File x...\Physical\xxx |
Could not find a component in the specified file. Check the eden code. |
Information - Unknown Label Component xxx for Commodity Code xxx |
The label component is unknown. Check the value in the label file. |
Information - Cannot Decode Label Number xxx for Commodity xxx Bore xxx |
An error occurred while trying to decode a label. |
Information - Cannot Determine Radius for Trimable Elbow (xx Degree Assumed) xxx |
The specified angle string could not be found in the description. The reported angle is assumed. |
Information - Standard Note File ...\Dat\CODExxx Cannot be found [n] Has not been decoded for xxxxx Bore xx |
The Standard Note file Codexxx.edt is missing from the Dat sub-directory. The requested note number cannot be determined. |
Information - Note Number [n] Cannot be found in Standard Note file ...\Dat\CODExxx Label has not been decoded for xxxxx Bore xx |
The Standard Note file Codexxx.edt does not contain the requested Note number. The requested note number cannot be determined. |