Open the Piping Specifications.xls workbook.
-
Select the OutsideSurfaceTreatment sheet.
-
Select a row after the Start keyword but before the End keyword, and click Insert > Row.
-
In the Nominal Piping Diameter From column, type the nominal pipe diameter (NPD) that specifies the start of the treatment range.
-
In the Nominal Piping Diameter To column, type the NPD that specifies the end of the treatment range.
-
In the Nominal Piping Diameter Units column, type the units for the NPDs. For example, type mm or in.
-
In the Environmental Zone column, specify where the piping is located.
-
In the Outside Surface Treatment column, select the exterior surface treatment that you want to use for the defined NPD range, if needed.
-
In the Coating Type column, select the coating type that you want to use for the defined NPD range, if needed.
-
In the Auxiliary Treatment column, select the auxiliary treatment, if needed.
-
Save and bulkload the workbook.
-
For more information about each exterior surface treatment property that you can define, refer to Exterior Coating and Surface Treatment.
-
The OutsideSurfaceTreatment sheet in the Piping Specification.xls workbook corresponds to the Exterior Coating and Surface Treatment Rule node in the Catalog task.