Add Report Definition Unique ID on the module - Intergraph Smart WQMS - 6.0 - Customization & Programming - Hexagon PPM

Intergraph Smart Weld Quality Management System Custom Reports

Language
English
Product
Intergraph Smart WQMS
Search by Category
Customization & Programming
Smart WQMS Version
6

After creating the Report definition Unique ID, it must be specified on the module definition.

To specify the Report Definition Unique ID on the module Definition:

  1. Navigate to the installation path ...\\SmartPlant\Smart WQMS\Models.

  2. Open WQMS-Modules Excel file.

  3. Navigate to ModuleSpecificProperties sheet > UpdateInstrutions section and edit the following property:

    This sheet contains the list of all views except the NOI/ROI views of Smart Weld Quality Management System.

    • WQMSCustomReportDef - Specify the Report UID in this property.

      For example:

      • If you want to place an icon in the Welder Qualification Test section in Welder module, enter "WelderQualificationTest:Report_Definition_Unique_ID" against the Update_WQMSAdminModule_ReferenceData_Welders field.

      • If you want to place the icon in Passed tab of the Welder Qualification List, enter "WelderQualificationList_PassedWQs:Report_Definition_Unique_ID" against the Update_WQMSAdminModule_ReferenceData_Welders field.

      • If you want to place icon in multiple sections, like Welder Log, Welder Qualification Test, and Welder Qualification List, enter "Welder:Report_Definition_Unique_ID|WelderQualificationTest:Report_Definition_Unique_ID|WelderQualificationList_PassedWQs:Report_Definition_Unique_ID" against the Update_WQMSAdminModule_ReferenceData_Welders.

        If there are more than one Report Unique IDs then you can separate the Unique IDs with a comma ",".

To generate custom reports from the NOI or ROI module:

  1. Navigate to the installation path ...\\SmartPlant\Smart WQMS\Models.

  2. Open WQMS-Modules Excel file.

  3. Navigate to InspectionDef sheet > WQMSInspectionDef section and edit the following properties:

    • WQMSInspDefNOICustomRptDef - Specify the Report Unique ID to generate the report from the NOI.