Transfers - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Specifies the list of components to be transferred from one sort group to another.

Open the grid, and then define the attributes listed below as needed.

  • IDF Record Identifier specifies the record ID of the component type. This is the intermediate data file (IDF) record number for the component, such as 107 for a blank flange or 90 for a control valve. Valid IDs are integers in the range 0-999. For more information, see Appendix: Record Identification Numbers.

  • New Group specifies a new group for the component type. Available sort groups include:

    • PIPE (pipe)

    • VALV (valves and inline items)

    • FITT (fittings)

    • INST (instruments)

    • FLAN (flanges)

    • SUPP (supports)

    • GASK (gaskets)

    • MISC (miscellaneous)

    • BOLT (bolts)

    • WELD (welds)

  • SKEY transfers a record ID to a component group based on a user-defined SKEY. In the example below, record ID 90 (instrument) is transferred to the valve group (VALV) but only instruments that have an SKEY of CV** (refers to a control valve with any end preparation).

    RecordID Group SKEY

    90       VALV  CV**

The value that displays on the Transfers icon is a count of how many components are specified for transfer. The example below indicates that 3 components are currently defined.