Drawing Splitting in Pipe - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the actions taken by the software whenever the Isogen automatic pipeline split facility selects a split point that is located in a straight length of pipe.

  • Normal uses the default for pipeline splitting to function as normal when the split point occurs along a section of pipe. The relevant split point information is passed back to the 3D design system using the isometric repeatability file, if it is being used.

  • Reject writes the warning message, UNACCEPTABLE SPLIT POINT, to the message file if a pipeline split occurs along a section of pipe. No plots are produced and no information is written to the isometric repeatability file for the pipeline.

  • Message writes the warning message, UNACCEPTABLE SPLIT POINT, to the message file if a pipeline split occurs along a section of pipe. Plots are produced with the message, UNACCEPTABLE SPLIT POINT plotted at the top of each affected drawing. No information is written to the isometric repeatability file for the pipeline.

Defines:

Option Switch - 108, Pos 1
I-Configure - Drawing.Controls.PipelineSplittingInTube