Component Attributes - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Lists the attributes available to all components.

Double-click an attribute name to add it to the Report Layout area. Alternatively, click Add Attribute . Then use the options in the Report Definition panel to configure the report as needed. For more information, see Define the report layout.

Not all of the component attributes listed below are permissible for all report types. As such, the report that is currently active in the Report Definition panel determines which component attributes appear in the attributes list.

Attribute Name

Description

Angle

Value of the angle in hundredths of degrees for elbow, bend, tee, cross, bend-teed, and elbow-teed type components.

Assembly-ID

Bolt assembly identifier.

Auto Generated

Indicator for whether the software automatically assigns and creates bolt sets.

Bend-Radius

Allowable radius of a standard pulled bend.

Bend-Radius-Multiplier

NPD multiplier used to define the bend radius.

Bolt-Dia

Units of dimensions (in or mm) used for bolt diameter.

Bolt-Item-Code

Unique identifier for the bolt component.

Bolt-Item-Description

Material description for bolts with the same item code.

Bolt-Length

Units of dimensions (in or mm) used for bolt length.

BOP-Elevation

Bottom of pipe elevation. Overrides the standard elevation output for tees, crosses, and elbows.

Characteristic Bore

Commonly written description of the bore, such as 25x25mm.

COMPONENT-Attribute1 to
COMPONENT-Attribute100

User-specified component attribute. Up to 100 attributes can be defined and can be used for any purpose.

Component-Remark- Number

Associates a text remark with a component. The remark information appears on the material list in two areas:

A cross-reference number against the component.

In list of remarks output at the bottom of the material list with a cross-reference against each remark.

Coords-X

X coordinate.

Coords-Y

Y coordinate.

Coords-Z

Z coordinate.

Co-ords-On

Internal piping object data (POD) file field.

Cost-Factor

Explicitly defined value used by Isogen to calculate weld diameter totals.

Cut-Piece-Length

Value for the required cut piece length of the pipe or bend. Overrides Isogen's normal cut piece length calculation.

Dial-Face-Direction

Direction of face on instrument dials and balloons.

Equipment Centre
Point X

Coordinate at the X position related to the center or intersection of the component.

Equipment Centre
Point Y

Coordinate at the Y position related to the center or intersection of the component.

Equipment Centre
Point Z

Coordinate at the Z position related to the center or intersection of the component.

Equipment Non Primary Orientation

Direction of the equipment.

Equipment Shape

Shape of the equipment to be output.

Equipment Shape 2

Shape to be plotted at the exit end of a piece of equipment.

Equipment Size X

Size of the rectangular-shaped equipment (cross-section at the X position).

Equipment Size Y

Size of the rectangular-shaped equipment (cross-section at the Y position).

Equipment Size Z

Size of the rectangular-shaped equipment (cross-section at the Z position).

External UCI

System-generated unique component identifier.

Flange-Left-Loose

Trigger that indicates the flange is to be left loose for fitting at site.

Flange-Cut-Minus

Negative cutting allowance for flange types with SKEYs such as FLRC, FLRE, FLSO, and FOSO. Allowance is used when calculating cut pipe length.

Flange-Cut-Plus

Positive cutting allowance for flange types with SKEYs such as FLFL or FLSJ. Allowance is used when calculating cut pipe length.

Flat-Direction

Direction of flat side of eccentric reducer.

FlyText

Concise summary of the properties for the currently select object.

Gasket-Class

Design class for special transition gasket used on fixed length type line pipe.

Gasket-Rating

Pressure rating for special transition gasket used on fixed length type line pipe.

Gearbox

Gearbox orientation direction.

Ignored Tube

Indicator for whether the pipe is ignored. That is, the component is neither considered in the computation of system dimensions nor is it displayed on the isometric drawing.

Insulation

Trigger that indicates the component is or is not insulated.

Insulation Specification

Insulation specification. Indicates a specification change on the plotted isometric.

Item Code

Unique material identifier for the component.

Item-Description

Material description for components with the same item code.

Item-Group

Component group.

Length

Leg length.

Jacket

Indicator for whether the component is part of a jacketed system.

Jacket-Spec

Jacket specification reference.

Material-List

Indicator for how the pipe or component is handled on the material list on the generated drawing (include or exclude).

Misc-Spec1 to
Misc-Spec5

Alternative user-defined specification. Indicates a specification change on the plotted isometric.

Name or Tag

User-defined identifier for a component.

Nozzle Coordinates X

Coordinate at the X position of the nozzle.

Nozzle Coordinates Y

Coordinate at the Y position of the nozzle.

Nozzle Coordinates Z

Coordinate at the Z position of the nozzle.

Nozzle Diameter

Units of dimensions used for the nozzle.

Nozzle Direction

Direction of the nozzle.

Nozzle End Prep

End preparation for the nozzle.

Nozzle Non Primary Direction

Direction of the nozzle.

Nozzle Position

Relative position of the nozzle in relation to the equipment.

Orifice Tap Direction

Direction of tapping connection on orifice plate.

Painting Specification

Painting specification reference. Indicates a specification change on the plotted isometric.

Part Number

Alternative part number used by Isogen instead of its automatically generated one.

Piping Specification

Primary specification to which the component belongs.

Plant

String that identifies a specific area of the plant.

Plant-Area

Plant Area identification number.

Plate-Direction

Orientation of the penetration plate.

Plate-Thickness

Thickness of the penetration plate.

Port-Reference1 to
Port-Reference10

Port reference number for a multi-port component.

Quantity

Number of items to be associated.

Revision

Pipeline revision at which the component was introduced.

Rotation-Angle

Angle of rotation in degrees clockwise.

Sequence Number

Internal POD field.

SHEET

Sheet number.

Size1

Size of the main pipe.

Size1 Units

Units of dimension for the size of the main pipe.

Size2

Size of the branch pipe.

Size2 Units

Units of dimension for the size of the branch pipe.

Size3

Size of the tertiary bore.

Size3 Units

Units of dimension for the tertiary bore.

Slip-Plate-Tail- Direction

Direction of tail on slip plate, slip ring, or spectacle blind.

Spindle-Direction

Direction of spindle (operator) on a valve.

Status

Trigger to indicate that a component is part of a special status, such as ON HOLD or EXISTING, section on a pipeline.

Support-Direction

Direction of user-defined support symbol.

Suppress-Item-Code

Indicator for whether the component displays in the material list.

Tap-Point

Internal POD field.

Thickness/Rating

Attribute in the welding definition file (WDF) to extract the data value from the THICKNESS-RATING attribute on a WELD record.

Tracing

Trigger that indicates whether a component is traced.

Tracing Specification

Alternative tracing specification. Indicates a specification change on the plotted isometric.

Unique-Component- Identifier

Unique database identifier generated by the host system for each component.

Waste

Basic wastage factor applied when the software calculates pipe lengths.

Weight1 / Weight2

Weight on fabricated tees and crosses with unequal branch bores. Weight1 is for BRANCH1 pipe, and Weight2 is for BRANCH2 pipe.

Weld-Attribute1 to
Weld-Attribute100

User-specified weld attribute. Up to 100 attributes can be defined and used for any purpose.

Weld-Gap

Space between male welded ends of a welded joint.

Weld Number

System-generated number for welds that do not have weld numbers defined in the input data file (PCF or IDF).

Weld-Remark-Number

Associates a text remark with a particular weld. The remark information appears on the isometric drawing two areas:

A cross-reference number against the weld identifier in the weld box.

In a list of remarks that is output at the bottom of the material list with a cross-reference number against each remark.

Weld-Spec

Weld specification reference.

Weld-Type

Text identifier on a weld, as distinct from the weld SKEY or from implied end type.

Welding-Allowance

Denotes from which ends of the pipe have any associated field fit weld (FFW) allowances taken.

Window-Direction

Direction of window on sight glass.