Accuracy - Isogen - Reference

Isogen Isometric Drawing Options Reference

Language
English
Product
Isogen
Search by Category
Reference
Smart 3D Version
11 (2016)
Isogen Control Panel Version
2.0(2016)
Isogen Version
13.0(2016)

Controls the accuracy at which angle data is output on the isometric drawing.

Click Show Collapse ICP to display a gallery of shapes, and then select the appropriate setting.

  • Default outputs all angles to the Isogen default accuracy of 0.1 degrees with no trailing zeros. For example, 80.16 is output as 80.2 degrees, and 80.01 is output as 80 degrees.

  • Nearest Degree outputs angles to the nearest degree.

  • Nearest 10th Degree (1 decimal place) outputs angles to the nearest 0.1 degrees.

  • Nearest 100th Degree (2 decimal places) outputs angles to the nearest 0.01 degrees.

Defines:

Option Switch - 67, Pos 4
I-Configure - Drawing.Format.AngleAccuracy